Operating and Installation
Instructions
Ventilation System
DA 249-4
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 07 781 040
en - US, CA
Vedere la pagina 0
1 2 3 4 5 6 ... 39 40

Sommario

Pagina 1 - DA 249-4

Operating and InstallationInstructionsVentilation SystemDA 249-4To prevent accidentsand appliance damage,read these instructionsbeforeinstallation or

Pagina 2 - Contents

Turning on the fan^Press the On/Off button.The fan runs at power level "2".The On/Off indicator lights.Selecting the power level^ Use the &q

Pagina 3

If the power level indicators "1" and "4"flash, the automatic switch back is notactivated.^To activate the automatic switch backpr

Pagina 4 - COOKTOP GREASE FIRE:

Delayed Shut DownIf odors or smoke remain in the kitchenafter cooking has been completed, theDelayed Shut Down feature can beselected to allow the hoo

Pagina 5

Turning the lighting on/offThe overhead lighting can be turnedon and off independently of the fan.^Press the light button briefly to turnon the lighti

Pagina 6

Filter timersGrease filterA timer monitors the hours of fanoperation. The indicator for the greasefilter will light after 30 hours ofoperation. The gr

Pagina 7 - Functional description

Reprogramming the timersThe grease filter timer is preset to 30hours. This time can be lengthened orshortened to 20, 30, 40 or 50 hours.–A time of 20

Pagina 8

Reprogramming the charcoal filtertimerThe active charcoal filter can only beused in recirculation mode and can notbe used to exhaust fumes.The charcoa

Pagina 9

,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:Before cleaning or servicing thehood, disconnect it from

Pagina 10 - Operation

Grease filterThe decor panel and reusable metalgrease filter remove solid particles fromthe vented kitchen air (grease, dust,etc).The grease filter is

Pagina 11

Cleaning the grease filters^By hand: use a scrub brush with asolution of warm water and milddetergent.Do not use the pure detergent,aggressive all pur

Pagina 12

IMPORTANT SAFETY INSTRUCTIONS...3Functional description ...7Guide to the Venti

Pagina 13

Active charcoal filtersIn recirculation mode an activecharcoal filter must be used in additionto the grease filter. The charcoal filter isdesigned to

Pagina 14

Replace the active charcoal filter whenthe charcoal filter indicator lights.Replace the filter at least every6 months or when it no longer absorbsodor

Pagina 15

Changing the light bulbs,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:Before changing the light bulbs,d

Pagina 16

RepairsIn the event of a fault which you cannoteasily fix yourself, please contact theMiele Technical Service Department.^When contacting the Technica

Pagina 18

Installation InstructionsRead these instructions and the "Important Safety Instructions" before installingthis ventilation system.The instal

Pagina 20

Disposal of packing materialThe cardboard box and packingmaterials protect the appliance duringshipping. They have been designed tobe biodegradable an

Pagina 21

Appliance dimensions28

Pagina 22

1) Air outlet installed upwards forrecirculation mode2) and 3) Cut out area in wall orceiling for entrance of 6" (150 mm)ductwork or 5" (125

Pagina 23 - After Sales Service

READ AND SAVE THESEINSTRUCTIONSKeep these instructions in a safeplace and pass them on to any futureuser.Read these instructions carefullybefore insta

Pagina 24

Distance between cooktop and hood (S)Do not install this exhaust hood over cooktops burning solid fuel.Provided a larger distance is not given by the

Pagina 25 - Installation Instructions

The majority of the weight of theinstalled ventilation system will besupported by the lower retainingplate. It must be firmly attached tothe stud fram

Pagina 26

Installation32

Pagina 27 - Caring for the environment

a 2 protective shieldsprevent scratches to the chimneyduring installation.b 1 vent collarfor use with 6" (150 mm) exhaustductingc 1 reducing coll

Pagina 28 - Appliance dimensions

Protective filmThe casing is covered with a protectivefilm to prevent scratching duringtransport.^Peel off the film before installing thecasing parts.

Pagina 29

,WARNINGDanger of toxic fumes.Gas cooking appliances releasecarbon monoxide that can beharmful or fatal if inhaled.To reduce the risk of fire and topr

Pagina 30

– If the exhaust is ducted into aninactive flue, the air must be expelledparallel to the flow direction of theflue.Never connect an exhaust hood toan

Pagina 31 - Plywood backing

,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:All electrical work should beperformed by a qualified ele

Pagina 32 - Installation

Maximum load ...390WLighting ...2x20WVoltage ...120VFrequency ...60HzCircuit rating...

Pagina 34

~d) Before connecting the applianceto the power supply make sure that thevoltage and frequency listed on thedata plate correspond with thehousehold el

Pagina 35 - Air extraction

M.-Nr. 07 781 040 / 02Alteration rights reserved / 2011INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOSTCURRENT PRODUCT

Pagina 36

,WARNINGTO REDUCE THE RISK OFINJURY TO PERSONS IN THEEVENT OF A COOKTOPGREASE FIRE, OBSERVE THEFOLLOWING*:~a) SMOTHER FLAMES with a closefitting lid,

Pagina 37 - Electrical connection

Installation,WARNINGTO REDUCE THE RISK OFFIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS,OBSERVE THE FOLLOWING:~a) Installation work and electricalwiring mu

Pagina 38 - Technical data

The hood offers two modes ofoperation:Air extractionThe air is drawn in and cleaned by thedecor panel and the grease filter anddirected outside.The ho