Descriptive Technical
Documentation
- Model-dependent -
DTD no. 521-7135
Model(s): PT 7135 C, PT 7136, PT 5135 C,
PT 5136
14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
Vedere la pagina 0
1 2 3 4 5 6 ... 87 88

Sommario

Pagina 1 - DTD no. 521-7135

Descriptive TechnicalDocumentation- Model-dependent -DTD no. 521-7135Model(s): PT 7135 C, PT 7136, PT 5135 C,PT 513614.10.2005, DE_en This information

Pagina 2

4 Touch current measurementxNoteOn machines with an earth connection, touch current leakage measurementsshould be carried out on all accessible conduc

Pagina 3 - Contents

B Modification HistoryWhen? Who? What?11.05.2005 Olaf Meyer zu Drewer Initial compilationDescriptive Technical DocumentationDTD no. 521-7135 B-114.10.

Pagina 4

Descriptive Technical DocumentationB-2 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights reser

Pagina 5 - 090 Electrical components

C Technical DataSemi-commercialmachinesPT 7135 C PT 7136 PT 5135 C PT 5136Condenser dryer Vented dryer Condenser dryer Vented dryerCasing Generation 2

Pagina 6 - 4 DTD no. 521-7135

Descriptive Technical DocumentationC-2 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights reser

Pagina 7 - 1 General information

D Layout of Electrical ComponentsPT 7135 CxLayout 11 (Z1) Interference suppression capacitor2 X3/1 Mains terminal strip3 (1K1/1, 2K1/1, 3K1/1) Heating

Pagina 8 - A-2 DTD no. 521-7135

11 (2R30) Drying air NTC temperature sensor - In heater bankbehind perforated rear drum panel12 (R1, R2, R3) Heater bank13 (A2) Door lock14 (C5) Capac

Pagina 9

PT 5135 CxLayout 21 (Z1) Interference suppression capacitor2 X3/1 Mains terminal strip3 (1K1/1, 2K1/1, 3K1/1) Heating relay4 (X1/1) Payment system soc

Pagina 10 - 4 Touch current measurement

12 (R1, R2, R3) Heater bank13 (A2) Door lock14 (C5) Capacitor - Drum drive15 (M5) Motor - Air flow and drum drive16 (1R30) Drying air NTC temperature

Pagina 11 - B Modification History

PT 7136xLayout 31 (Z1) Interference suppression capacitor2 (X3/1) Mains terminal strip3 (1K1/1, 2K1/1, 3K1/1) Heating relay4 (X1/1) Payment system soc

Pagina 12 - B-2 DTD no. 521-7135

This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.2005, DE_en

Pagina 13 - C Technical Data

12 (A2) Door lock13 (C5) Capacitor - Drum drive14 (M5) Motor - Air flow and drum drive15 (S32) Safety switch - Finger protection16 (1R30) Drying air N

Pagina 14 - C-2 DTD no. 521-7135

PT 5136xLayout 41 (Z1) Interference suppression capacitor2 (X3/1) Mains terminal strip3 (1K1/1, 2K1/1, 3K1/1) Heating relay4 (X1/1) Payment system soc

Pagina 15 - PT 7135 C

12 (A2) Door lock13 (C5) Capacitor - Drum drive14 (M5) Motor - Air flow and drum drive15 (1R30) Drying air NTC temperature sensor - Fill ring16 (R1, R

Pagina 16

020 DoorxDescriptive Technical DocumentationDTD no. 521-7135 020-114.10.2005, DE_en This information should not be duplicated or passed on without Mie

Pagina 17 - PT 5135 C

2 Function2.1 Door lock (A2)Door release via Bowden cable.An open door is registered via a microswitch in the door lock.Microswitch in door lock (A2):

Pagina 18

030 Drum, bearing, sensors, heater bankxDescriptive Technical DocumentationDTD no. 521-7135 030-114.10.2005, DE_en This information should not be dupl

Pagina 19

1 Technical DataHeater bank (R1, R2, R3) Condenser dryer Vented dryerHeater rating with 230 Vconnection3-filament, 2-phase 3-filament, 3-phase1.94 kW

Pagina 20

Temperature (°C) Resistance (kΩ)190 0.852200 0.710Table 2: NTC temperature sensor - Heater bank (2R30) - Resistance valuesTemperature (°C) Resistance

Pagina 21

2 Function2.1 Heating control (R1, R2, R3)Safety features:If the fill ring temperature sensor (1R30) is defective, the heating is not activated.The he

Pagina 22

2.5 Light - Drum (H3/6)Lighting is time-controlled. It is switched on approx. 1 s after the door is opened.Switch off delay: 5 min.When the door is cl

Pagina 23 - 020 Door

ContentsGeneral InformationA Warning and Safety InstructionsB Modification HistoryC Technical DataD Layout of Electrical ComponentsFunction Groups020

Pagina 24 - 2 Function

Descriptive Technical Documentation030-6 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights res

Pagina 25 - DTD no. 521-7135 030-1

040 DrivexDescriptive Technical DocumentationDTD no. 521-7135 040-114.10.2005, DE_en This information should not be duplicated or passed on without Mi

Pagina 26 - 1 Technical Data

1 Technical DataCooling fan flow rate Condenser dryer Vented dryerCooling air 300 m3/ h –Drying air 120 m3/ h 300 m3/ h. With 20 m vent duct> 200 m

Pagina 27 - DTD no. 521-7135 030-3

2 Function2.1 Motor - Air flow and drum drive (M5)PT 7135 C, PT 5135 CThe motor drives the drum, drying air fan and cooling air fan at the same time.2

Pagina 28

Descriptive Technical Documentation040-4 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights res

Pagina 29 - 2.5 Light - Drum (H3/6)

070 Condensate pump (M5)PT 7135 C, PT 5135 CxDescriptive Technical DocumentationDTD no. 521-7135 070-114.10.2005, DE_en This information should not be

Pagina 30 - 030-6 DTD no. 521-7135

2 Function2.1 Level sensing - Float switch - Condensate (B8/7)Level sensing is via a reed switch.Descriptive Technical Documentation070-2 DTD no. 521-

Pagina 31 - 040 Drive

080 Fascia panelxDescriptive Technical DocumentationDTD no. 521-7135 080-114.10.2005, DE_en This information should not be duplicated or passed on wit

Pagina 32

1 Technical DataPT 7135 Cand PT 7136Cottons MinimumironAutomatic Outerwea Shirts Denim ProofingExtra dryNormal + - 2% 0% -2%Normal 0% 2% 0% 2% 0% 2% 0

Pagina 33

2 Function2.1 Overriding time controlAfter programme start, an overriding time control of approx. 180 min applies to allresidual moisture drying progr

Pagina 34 - 040-4 DTD no. 521-7135

2.4 Time of day programmable function . . . . . . . . . . . . . . . . . . . . . . . 080-32.5 Extended cooling phase programmable function. . . . . . .

Pagina 35 - 070 Condensate pump (M5)

2.5 Extended cooling phase programmable functionAn extended cooling phase means that the laundry temperature is lower at theend of the programme.A low

Pagina 36

2.7 Clean the airways warning modification programmable functionThis function can be used to modify the circumstances under which the Clean theairways

Pagina 37 - 080 Fascia panel

2.10 Clean heat exchanger programmable functionPT 7135 C, PT 5135 CWith a condenser dryer this warning is shown at intervals and indicates that thehea

Pagina 38

2.13 Payment system programmable functionThis is used to set the type of payment system. The appropriate operatingprocedure is shown in the display.Fo

Pagina 39

2.16 Overriding time control modification programmable function withpayment system operationTo reduce the possibility of unauthorised manipulation wit

Pagina 40

2.19 Warm air timed programme maximum duration settingprogrammable functionThis is used to set the maximum duration of the Warm air timed programme.PT

Pagina 41

3 Fault Repair3.1 Warning indication: Clean filterPT 7136CauseThis warning is given at certain intervals as a reminder that the filters must becleaned

Pagina 42 - PT 7135 C, PT 7136

3.2 Warning indication: Clean heat exchangerPT 7135 C, PT 5135 CCauseWith a condenser dryer this warning is shown at intervals and indicates that theh

Pagina 43

3.3 Warning indication: Adjust the load – The drum is empty or thelaundry too drySymptomThis warning can only be displayed with residual moisture dryi

Pagina 44

3.4 Demonstration mode activeSymptomA programme start is not possible and the programming and service modescannot be accessed.CauseThe demonstration m

Pagina 45

4.6 Service mode summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 080-38090 Electrical components2 Function . . . . . . . . .

Pagina 46 - 3 Fault Repair

RemedyA Check the condensate pump (M13). Exchange it if necessary.A PT 7135 C and PT 7136: Service mode, see Service mode summary, 080 4.5.A PT 5135 C

Pagina 47

CauseClean the airways warning shown too early/late.RemedyA The point at which the Clean the airways warning is shown can be adjustedto suit the needs

Pagina 48

3.8 Fault code F1, heater bank NTC sensor short-circuitedSymptomIn normal operation mode the display shows Technical fault.Programme interruption, coo

Pagina 49 - 3.4 Demonstration mode active

CauseHeater bank not heating.RemedyA Check the heater bank (R) for short or open circuit.CauseHeating relay (K1).RemedyA Check the heating relay (K1).

Pagina 50

3.11 Fault code F4, fill ring NTC sensor open-circuitedSymptomIn normal operation mode the display shows Technical fault.Programme interruption, cooli

Pagina 51

3.13 Fault code F43, model type not programmedCauseIn normal operation mode this fault is not indicated via the display.The selection module (EW) and

Pagina 52

3.15 Fault code F46, display faultSymptomProgramme interruption, cooling down phase, intermittent buzzer operation.CauseInternal display fault on sele

Pagina 53

3.17 Fault code F50, motor stationary and heating operates for 5 sSymptomThe motor for air flow and drum drive (M5) is stationary.This fault occurs in

Pagina 54

CauseAir path clogged.RemedyA Check and clean the air paths.CauseHeater bank not heating.RemedyA Check the heater bank (R1) for short or open circuit.

Pagina 55

3.19 Fault code F66, air leakage faultSymptomIn normal operation mode the display shows Clean the airways.CauseAir path clogged.Insuf ficient air flow

Pagina 56

Descriptive Technical Documentation4 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights reserve

Pagina 57

4 Service4.1 Programming mode summaryPT 7135 C, PT 7136Initial requirementsA Finish or cancel any programme in operation, including the demonstrationm

Pagina 58

OptionsThe set option is indicated by a V next to it.A Programmable function selection: Turn the multifunction selector switch tomark the desired func

Pagina 59

xProgrammable function OptionLanguage Language for operating, programming and service modesSort language Select and sort four favourite languages for

Pagina 60 - 4 Service

Programmable function OptionClean filters warning, vented dryers only,see 080 2.9 Clean filters programmablefunctionOffDisplay after 5 hDisplay after

Pagina 61

Programmable function OptionOverriding time control modification withpayment system operation, see 080 2.16Overriding time control modificationprogram

Pagina 62 - 080-26 DTD no. 521-7135

Save and quitxNoteConfirmed programmable options are saved.A Reconnect the fill ring NTC temperature sensor (1R30) plug.4.2 Programming mode summaryPT

Pagina 63 - DTD no. 521-7135 080-27

The display shows the Service Dept. programmable functions.If the accessing procedure has been unsuccessful, the control automaticallyreverts to the n

Pagina 64 - 080-28 DTD no. 521-7135

Programmable function OptionResidual moisture level adjustment -Minimum ironThe standard residual moisture levels can be modified to make them up to3

Pagina 65 - 4.2 Programming mode summary

Programmable function OptionProgramme lock with payment systemoperation after releasing the Start button,see 080 2.17 Programme lockprogrammable funct

Pagina 66

4.3 Demonstration mode activation / deactivationPT 7135 C, PT 7136Initial requirementsA Finish or cancel any programme in operation.A Open the door.A

Pagina 67 - DTD no. 521-7135 080-31

A Warning and Safety Instructions1 General informationService and repair work should only be carried out by suitably qualified persons inaccordance wi

Pagina 68

Save and quitA Demonstration programme deactivation: Repeat the accessing procedure.4.4 Demonstration mode activation / deactivationPT 5135 C, PT 5136

Pagina 69

xNoteAfter an interruption in the mains supply, the demonstration mode programmebegins again automatically.Save and quitA Demonstration programme deac

Pagina 70 - PT 5135 C, PT 5136

OptionsA Service function selection: Turn the multifunction selector switch asappropriate.A Service function start and test step advance: Press the mu

Pagina 71 - 4.5 Service mode summary

Service function Component / Sensor testedComponent activationComponent activation Function tested/Machine responseAll components InactiveDrive/Fan mo

Pagina 72

Quit (without saving)A Open the door.4.6 Service mode summaryPT 5135 C, PT 5136Initial requirementsA Ensure the machine is installed and connected cor

Pagina 73 - DTD no. 521-7135 080-37

xNoteThe service mode is switched off automatically 30 min after the last servicefunction has been checked.Service function Component / Sensor testedS

Pagina 74 - 4.6 Service mode summary

Service function Component / Sensor testedComponent activationComponent activation Function tested/Machine responseAll components InactiveDrive/Fan mo

Pagina 75 - DTD no. 521-7135 080-39

Service function Component / Sensor testedControls Display / LED test All display points flash at the same timeAlle LEDs and the illuminated switch su

Pagina 76 - 080-40 DTD no. 521-7135

Descriptive Technical Documentation080-42 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights re

Pagina 77 - DTD no. 521-7135 080-41

090 Electrical componentsxDescriptive Technical DocumentationDTD no. 521-7135 090-114.10.2005, DE_en This information should not be duplicated or pass

Pagina 78 - 080-42 DTD no. 521-7135

2 Risk of injury due to sharp edgesThere may be a risk of injury due to sharp edges.Protective gloves should be worn and the edge protection, Mat. no.

Pagina 79

2 Function2.1 Mains terminal strip (X3/1)PT 7136, PT 5136Depending on the country version, the mains terminal strip (X3/1) has a 4-/5-poleconnection c

Pagina 80

2.4 Central control via RS 232 interface with 9-pole plugPT 7135 C, PT 7136Possible to use one central control/payment system.Control data can be read

Pagina 81 - DTD no. 521-7135 090-3

4 Service4.1 Fitting payment system on machine lidA Remove the machine lid.xFig. 1Warning!When drilling through the machine lid, take care to not dril

Pagina 82

4.2 Payment system (programme operation)xNoteThe instructions given in the documentation provided with the payment systemmust be followed.Fig. 3A Open

Pagina 83

4.3 Payment system (timed operation)xNoteThe instructions given in the documentation provided with the payment systemmust be followed.Warning!The conn

Pagina 84

A Set the tumble dryer payment system programmable option to Timedoperation.A PT 7135 C and PT 7136: For Service Dept. programming mode seeProgramming

Pagina 85

xFig. 5Fig. 6A Unscrew and remove the mains connection box lid. Loosen the cable strainrelief.A Pass the data cable through the casing opening for the

Pagina 86

A At the payment system socket (X1/1), cut either through the wire bridge 1W14between pins 1 and 2 or the wire bridge 2W14 between pins 3 and 5 asdesi

Pagina 87

Descriptive Technical Documentation090-10 DTD no. 521-7135This information should not be duplicated or passed on without Miele approval. All rights re

Pagina 88 - 090-10 DTD no. 521-7135

3 Electrical connection via plug connectorIt is always recommended to make electrical connection via a plug and socket sothat electrical safety checks