Installation of multiple
appliances
When installing more than one combiset appliance, a support bar b must be
installed between the appliances.
Countertop cut-out
two appliances
For the installation of two appliances
the width of the countertop cut-out D is
the sum of A and C.
A, B and C = appliance widths
11
5
/
16
", 15" or 22
11
/
16
"
(288 mm, 380 mm or 576 mm)
minus
5
/
16
"(8mm)to allow for the
overhang
D = width of the countertop cut-out
Countertop cut-out
three appliances
For the installation of three appliances
the width of the countertop cut-out D is
the sum of A and B and C.
If more than three appliances are
being installed, you will need to add,
A, B or C for each additional
appliance.
Installation
37
C
D
A
b
(500 m
m)
+
-
1
11/16"
19
C
D
A
B
b
(500 mm)
+
-
1
11/16"
19