6.2.9 Fault Code F16
Cause
Identity lost, programmed model variant has been deleted
Remedy
Reprogram the model variant
6.2.10 Fault Code F17
Cause
The catalyser temperature sensor Pt 1000 is open-circuited or its
resistance is too great
Remedy
Replace the Pt 1000 sensor