Vedere la pagina 46
When converting to another type of
gas, the main jets and the small jets
on all burners have to be changed.
Screw in new jets appropriate to the
type of gas, according to the
following table.
Jet table
For U.K. and IE
Main jet C Small jet C
Natural gas
Small burner
Normal burner
Large burner
Extra large burner
Wok
0.75
0.90
1.11
1.22
1.47/Kz34
0.39
0.42
0.42
0.54
0.88 / 0.42
Liquid gas
Small burner
Normal burner
Large burner
Extra large burner
Wok
0.54
0.67
0.71
0.77
0.98/Kz7
0.23
0.23
0.32
0.40
0.60 / 0.23
The jet markings refer to 1/100 mm of the jet diameter.